Silvercrest Adaptor Set Instrucciones de operaciones Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
CEHR
7
Setting a day programme (weekdays individually)
Example: At the weekend the heating period begins at 08:00
Action Display Description
The number of the selected
weekday flashes.
Set
for Saturday.
The currently preset beginning of
the heating period flashes.
Set the desired heating period.
The currently preset beginning of
the economy period flashes.
Skip the next two switching times.
Set
for Sunday.
Repeat the same setting for
Sunday as for Saturday.
Back to controlled operation
.
The CEHR changes to automatic mode and operates
immediately with the changed switching times for the weekend.
Deleting the switching times
The CEHR always requires two switching times per heating period
(beginning and end).
Action Display Description
The number of the selected
weekday flashes.
Set
for Saturday.
Set the desired switching time, for
example in the day programme.
Turn the rotary knob until this
display is shown.
The second switching time of the
heating period flashes.
Turn the rotary knob until this
display is shown.
Return to controlled operation.
The setting is between 23:50 and 0:00 hours.
Turn slowly in this range to ensure that you do not skip the desired
setting.
The CEHR now operates without the deleted switching times.
The manual mode is particularly suitable for the following cases:
During your holiday the CEHR is to keep a constant (lower)
temperature.
If you want to switch off the radiator in summer.
Constant temperature without time programme (holiday)
Action Display Description
Switch to manual mode.
Set the desired temperature.
The CEHR holds the preset temperature until you switch back to
automatic mode.
Switching off the radiator (Summer mode)
Action Display Description
Switch to manual mode.
Turn the rotary knob to the left until
OFF is displayed.
The radiator valve is now closed, the CEHR does not operate.
Frost protection and valve protection are still ensured.
Terminating manual mode
Action Display Description
Manual mode
Switch to automatic mode
The CEHR operates in automatic mode again.
You can disable the operating elements of the CEHR against
unauthorised operation.
Disabling the operating elements (child-lock)
Keep the
AUTO
MANU
and button pressed simultaneously for
3 seconds.
The message
is displayed. No settings can be changed
at the CEHR.
Reversing disabling
Keep the
AUTO
MANU
and button pressed simultaneously for
3 seconds again. The CEHR switches back to normal display.
1. Remove the operating unit and remove the batteries.
2. Press and hold all 3 buttons while inserting the batteries at
the same time.
3. Put the operating unit back on.