Section 2
Fault Code Diagnostics
14
34 7 PID 22 Mechanical failure of the clutch
actuator assembly solenoids
If possible, retrieve ISO fault code using TransSoft or if
applicable, perform procedure for retrieving fault codes
using the transmission shift lever. Follow the ISO fault
code repair instructions. Contact OnTrac at
866-668-7221 and request a ZF-FreedomLine
transmission specialist.
35 3 SID 23 Short circuit to positive at the output
stage to the high range solenoid
(Y9)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace lower part of TCU. Contact OnTrac
at 866-668-7221 and request a ZF-FreedomLine
transmission specialist.
35 5 SID 23 Open circuit at the output stage to
the high range solenoid (Y9)
When submitting a warranty claim under standard
warranty conditions, the complete TCU should be
replaced and the entire unit submitted with warranty
claim. Out-of-warranty only and/or no warranty claim
submitted, replace lower part of TCU. Contact OnTrac
at 866-668-7221 and request a ZF-FreedomLine
transmission specialist.
35 6 SID 23 Short circuit to ground at the output
stage to the high range solenoid
(Y9)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU. Contact OnTrac at
866-668-7221 and request a ZF-FreedomLine
transmission specialist.
36 3 SID 24 Short circuit to positive at the output
stage to the low range solenoid (Y8)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
36 5 SID 24 Open circuit at the output stage to
the low range solenoid (Y8)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
36 6 SID 24 Short circuit to ground at the output
stage to the low range solenoid
(Y8)
When submitting a warranty claim under
standard warranty conditions, the complete TCU
should be replaced and the entire unit submitted
with warranty claim. Out-of-warranty only
and/or no warranty claim submitted, replace
lower part of TCU.
Contact OnTrac at 866-668-7221 and request a
ZF-FreedomLine transmission specialist.
SAE Fault Code Repair Instructions
SAE J1587 Fault
Code
Instrument
Panel
Display
Fault Code Fault Description
Repair Instructions
NOTE: The following repair instructions pertain
to active faults only. For information and
instructions about inactive faults, please
contact OnTrac at 866-668-7221 and request a
transmission specialist.Fault FMI